14 “SUPER FREEZE” FUNCTION
This function allows all foods placed in the freezer to be frozen in the best possible way
(also for best preserving the qualities of the frozen foods).
Activating this function forces the compressor to stay on continuously in order to have
maximum freezing power for the freezer compartment. Two activation procedures are
possible for this function: the SUPER FREEZE 24h for freezing small quantities of
food with activation possible just before or even at the time of placing the food in the
compartment; the SUPER FREEZE 48h for freezing large quantities of food with
activation recommended 24h before placing the food in the compartment for already
having lots of cold available and to be able to complete the freezing with the second 24
hours of operation activated;
In the first case the function is ended after the 24h, or if the freezer air sensor measures
a temperature below 0 °C for 254 minutes. In the second case the function is ended
after the 48h.
If the SUPER FREEZE function is activated, there may be an immediate defrost if the
cumulated “compressor On” hours are more than 1 hour, otherwise the function
proceeds as specified.
Defrosts can occur during execution of the SUPER FREEZE function. In particular,
after the compressor has been on for 11 hours, it is switched off and a defrost is done,
which ends with the conditions already seen for normal operation; at the end of this
defrost, the compressor is switched on again to complete the remaining hours of
SUPER FREEZE function.
The SUPER FREEZE function can be activated in the appliance ON condition,
whereas it is never possible in that of appliance OFF. The SUPER FREEZE cannot be
activated if one of the two alarm conditions (A1 or A2) exists, or if the HOLIDAY
function is active.
If the SUPER FREEZE 24h function is activated by means of the refrigerator door
display (when present), the icon on the display remains on (fixed), whereas for the
SUPER FREEZE 48h function the same icon comes on flashing, indicating activation
and execution of the first 24h; after the first 24h of activation the icon remains on
(fixed), indicating the start of the second 24h. The area on the display relevant to the
freezer compartment continues to show the temperature set by means of the user
adjustment, which will become active again only at the end of the SUPER FREEZE
function (irrespective of 24h or 48h).
For the standard models, on activating the function by means of the special key on the
appliance control panel, the relevant LED remains on (fixed), whereas for the SUPER
FREEZE 48h function the same LED comes on flashing, indicating activation and
execution of the first 24h; after the first 24h of activation the LED remains on (fixed),
indicating the start of the second 24h.
Switching the appliance off (ON/OFF key on the display) automatically involves
deactivation of the function. Activation of one of the two alarm modes (see paragraph
“Alarm Management”) automatically involves deactivation of the function, if the alarm
condition is reset, the function is not reactivated.