13 “HOLIDAY” FUNCTION
This function offers temperatures optimized for preserving foods with the lowest
permissible consumption in case of minimum use of the refrigerator compartment:
particularly in the case of medium-long holidays when the freezer can remain full and
with the refrigerator empty.
This function is activated to set a cycle (refrigerator switching On threshold 15 °C,
refrigerator switching Off threshold 13 °C; freezer switching On threshold -16 °C,
freezer switching Off threshold -20 °C) programmed for keeping the refrigerator and
freezer compartments at given temperatures that will also be shown on the display
(when present) in the area relevant to the freezer compartment and fridge.
The function cannot be activated with the appliance on logic OFF and if one of the two
possible alarm conditions (A1 or A2) is active.
For display models the function is activated by means of the refrigerator door display
with its relevant signalling; for standard models, by turning the refrigerator knob all the
way anticlockwise - this event is signalled by the buzzer beeping twice. The function is
deactivated by means of the refrigerator door display or when the appliance is switched
off (ON/OFF key on the display). For standard model the function is deactivated by
positioning the refrigerator knob outside the relevant limit area. Upon deactivation, the
buzzer beeps once, confirming the exiting of that function, and the adjustment set by
the user by means of the knobs is reactivated.
If one of the two alarm conditions (A1 or A2) exists with the HOLIDAY function
active, the HOLIDAY function is not deactivated, however the alarm status prevails,
performing particular cycles in the freezer; when the alarm is deactivated the
HOLIDAY function operates normally again. The HOLIDAY function cannot be
activated in the alarm condition.
If the HOLIDAY function is active, the SUPER FREEZE and SUPER COOL functions
cannot be activated. If SUPER FREEZE or SUPER COOL are already active and the
HOLIDAY function is activated, SUPER FREEZE or SUPER COOL will be regularly
completed and then the HOLIDAY function will start operating. If the HOLIDAY
function is active, the ICE PARTY function cannot be activated. If ICE PARTY is already
active and the HOLIDAY function is activated, ICE PARTY will be terminated
immediately and the message to remove the bottle will be signalled to the user.
In case of freezer or refrigerator air sensor breakage, the function is time managed. In
case of a power failure while the HOLIDAY function is activated, when the power
comes on again it will reactivate automatically.