FULL NO FROST COMBINED UNIT (2003)
Technical Manual
GB 04-10-28/01 24-43
Language Issue/Edition Page
POSSIBLE CAUSE OF MALFUNCTION:
Board management
Monitoring circuit on the board
Connection on the board
Sensor wiring
TESTING:
General on appliance: carry out the check using the “Autotest” procedure;
Wiring and component: check for continuity and short circuits; check the
connections (connectors and terminals); check that the resistive values correspond to
the values given by the manufacturer (heat the probe touching it with your hand where
possible and check the variation in the resistive value).
Board: carry out a quick visual check of the board (breakages or burnouts, etc.); check
by using a replacement.